Coolant Inline Valves
With its innovative valve technology, Pierburg's inline valve enables optimum connection in terms of installation space by eliminating the usual axial offset between the input and output lines. Because the actuator is located in line with the coolant ports, this enables much more compact packaging in the vehicle. The lowest pressure losses of the Pierburg inline valve allow reduced power consumption of the volumetric pump as well as a significantly increased throughput. The patented valve design reduces pumping effects and thus minimizes switching noises.
Coolant Inline Valves Portfolio
2-way inline coolant swichting valve
Highlights
- Optimum installation space solution due to coaxial inlet and outlet design
- Flexible assembly in the space over 360°
- Optimized pressure drop performance for flow rates up to 60 l/min (3600 l/h)
- Fail safe open or closed freely selectable thanks to modular principle
Technical data | Normally open | Normally closed |
---|---|---|
Operating voltage | 12/24 V | 12/24 V |
Ambient temperatures | -40 °C to +140 °C | -40 °C to +140 °C |
Media temperatures | -40 °C to +140 °C | -40 °C to +140 °C |
Flow rate | up to 60 l/min | up to 60 l/min |
Pressure drop | 70 mbar at 25 l/min | 90 mbar at 25 l/min |
Max. differential pressure | up to 3,0 bar | up to 2,0 bar |
Internal leakage at 1,8 bar rel. | < 0,03 l/min | < 0,05 l/min |
3-way inline coolant switching valve
Highlights
- Various fail-safe configurations possible – inline passage or 90° outlet open or closed
- Optimum installation space solution due to coaxial inlet and outlet design
- Flexible assembly in the space over 360°
- Best pressure drop performance for flow rates up to 50 l/min (3000 l/h) for magnetic valve technology
- Use as a switching valve with 1 inlet and 2 outlets or 2 inlets and 1 outlet possible
Technical data | 1 inlet & 2 outlets | 2 inlets & 1 outlet |
---|---|---|
Operating voltage | 12/24 V | 12/24 V |
Ambient temperatures | -40 to +140 °C | -40 to +140 °C |
Media temperatures | -40 to +140 °C | -40 to +140 °C |
Flow rate | up to 50 l/min | up to 50 l/min |
Axial pressure drop | 110 mbar at 25 l/min | 120 mbar at 25 l/min |
Pressure drop 90 °C | 115 mbar at 25 l/min | 130 mbar at 25 l/min |
Max. differential pressure | up to 2.0 bar | up to 1.5 bar |
Internal leakage at 1,8 bar rel. | < 0.05 l/min | < 0.05 l/min |
Contact