General information

The floor areas of the expandable shelters are on one level when extended, so there are no steps or landings in the shelter interior. The design of ZEPPELIN-Shelters® always allows wall mounting of technical or medical equipment also in the expandable part as well as fixed mounting in the floor and ceiling area of the main shelter.

Depending on the design, the ZEPPELIN-Shelters® have a separate technical room on the front side for e.g. power supply and air conditioning. On request, the ZEPPELIN-Shelter® can be equipped with C-rails on the walls and in the floor for mounting the installation parts.

Especially for use in technical areas, the ZEPPELIN-Shelters® can be equipped with RF shielding (minimum shielding of 45 dB in the frequency range between 100 kHz and 1 GHz).

Optionally, the ZEPPELIN Container Shelters can achieve a ballistic protection level and be equipped with an NBC protection ventilation system.

The customer-specific equipment includes individual system integration (EDP, rack installation, communication technology, etc.) as well as lighting and furnishing.

Already during the design of the shelter cell, customer-specific reinforcements of the profile frames to accommodate heavy attachments, mounting points, lighting, cabling or supply openings and breakthroughs can be taken into account.

RMS always realizes design adaptations of the shelters to allow for special equipment, installations or attachments according to customer requirements.

The shelters can be individually interconnected by means of locks - special connecting shelters or pole or inflatable tents - and thus combined to form a complex, closed unit.

The operation of the ZEPPELIN-Shelter® is possible on a vehicle as well as on the ground.

Zeppelin shelter® 1:1
34759
34762
34765
34768

With an area of approx. 12 m², the ZEPPELIN-Shelter® 1:1 offers room quality at the highest level.

The operation of the ZEPPELIN-Shelter® 1:1 is possible on a vehicle as well as placed on the ground.

Technical data
Basic dimensions according to DIN ISO 20'
Outer dimensions
  • over corner fittings
    length 6.058 mm
    width 2.438 mm

    ISO 668 size 1C
    height 2.438 mm

    1CC
    height 2.591 mm


Dead weight (depending on version): 

  • approx. 2,800 kg


Permissible total weight (depending on version):

  • 8,000 - 10,000 kg
Zeppelin shelter® 2:1
34774
34777
34780
34783

The ZEPPELIN-Shelter® 2:1, which can be extended on one side, offers a significantly larger usable area of approx. 18 m² and flexibility of use, both for medical and technical applications.

The operation of the ZEPPELIN-Shelter® 2:1 is possible on a vehicle as well as on the ground.

Technical data
Basic dimensions according to DIN ISO 20'
Outer dimensions:
  • Shelter closed
    length 6.058 mm
    width 2.438 mm

    ISO 668 size 1C / 1CC
    height 2.438 mm / 2.591 mm
  • Shelter extended
    length 6.058 mm
    width 4.275 mm

    ISO 668 size 1C / 1CC
    height 2,438 mm / 2,591 mm


Dead weight (depending on version):

  • approx. 3,800 kg


Permissible total weight:

  • 10,000 kg
Zeppelin shelter® 3:1
34789
34792
34795
34798
34801

The ZEPPELIN-Shelter® 3:1 container, which can be expanded on two sides, offers the largest possible working area in this ZEPPELIN design with a room size of approx. 27 m².

The operation of the ZEPPELIN-Shelter® 3:1 is possible on a vehicle as well as on the ground.

 

Technical data
Basic dimensions according to DIN ISO 20'
Outer dimensions
  • Shelter closed
    length 6.058 mm
    width 2.438 mm

    ISO 668 size 1C / 1CC
    height 2.438 mm / 2.591 mm
  • Shelter extended
    length 6.058 mm
    width 6.275 mm

    ISO 668 size 1C / 1CC
    height 2,438 mm / 2,591 mm


Dead weight (depending on version):

  • approx. 3,800 kg


Permissible total weight:

  • 10,000 kg